Features:
- Ultimate Authentication Performance
- Advanced Elevator Control Functions
- Advanced Global Functionality based on peer-to-peer communication
- High Level Cyber Security
Specifications
Primary Power | PoE 802.3at / 12-24 Vdc +/-20%, 550 mA maximum (reader current not included) | ||||||||||||||||||||||||
Primary Host Communication | Ethernet: 100Base-TX 256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications |
||||||||||||||||||||||||
Secondary Host Communication | Bluetooth 5.2 | ||||||||||||||||||||||||
Third Host Communication | Wi-Fi IEEE 802.11ac 5GHz, or 2.4GHz/5GHz IEEE 802.11n 256bit AES* symmetric encryption for Controller to Server and Inter-Controller communications |
||||||||||||||||||||||||
Ethernet network connection | Port 1: Ethernet: 100Base-TX Port 2: Ethernet: 100Base-TX (Configurable for Port Failover) | ||||||||||||||||||||||||
RS-485 connection | Port 1: Armatura RS-485 / OSDP V2.2 Port 2: Armatura RS-485 / OSDP V2.2 Port 3: Armatura RS-485 / OSDP V2.2 (Configurable for Port Redundancy dedicated on port 2 & 3) |
||||||||||||||||||||||||
Number of Ports | 2*TCP/IP (IPv4 & IPv6) 3*RS-485 2*Wiegand 1*RS-232 |
||||||||||||||||||||||||
Inputs | 4 states supervision, resistor values (5% tolerance), Normally open contact: use 1.2k, 2.2k. 4.7k or 10k Normally closed contact: use 1.2k, 2.2k. 4.7k or 10k Dedicated Panel Tamper IO Input* Dedicated Microchip Control Fire Alarm IO Input & REX Input for catastrophic situation |
||||||||||||||||||||||||
Outputs | 1 relay, 1* Form-C with dry contacts | ||||||||||||||||||||||||
Normally Open Contact Rating | 5A @ 30Vdc resistive | ||||||||||||||||||||||||
Normally Closed Contact Rating | 5A @ 30Vdc resistive | ||||||||||||||||||||||||
On-Board Monitor | Dual Firmware Support, Access Control Mode (Standard) & Elevator Control Mode (Optional, Require Extra License for Activation) | ||||||||||||||||||||||||
On-Board Webserver | WebSever for System Configuration and Management Dashboard for Controller Status Mointoring, Device Firmware Swapping (Access Control Mode / Elevator Control Mode), Device Connection Status Monitoring & Configuration, Performanace Status, Sever Primary Controller Setting, Network Status Monitoring & Setting, IP Access Filter, SSL / TLS Certificates Setting, Access Log Export, Controller Reset, Debug Status Monitoring, Operation Log Monitoring, User Management, Date & Time Setting, Daylight Saving Time Setting, NTP Sever Setting, General Status, Controler Information |
RFID Card Capacity | As a Main-Controller: 800,000 (Storage) As a Door Unit: 400,000 (1:N) / 800,000 (1:1) |
||||||||||||||||||||||||
Maximum RFID Card Number Length | Supported up to 256-bits card number length | ||||||||||||||||||||||||
Mobile Credential Capacity | 400,000 (1:N) (Bluetooth) 400,000 (1:N) (NFC) 400,000 (1:N) (Dynamic QR Code) |
||||||||||||||||||||||||
Fingerprint Capacity | As a Primary Controller: 100,000 (Storage) As a Door Unit: 50,000 (1:N) / 100,000 (1:1) | ||||||||||||||||||||||||
Face Capacity | As a Primary Controller: 100,000 (Storage) As a Door Unit: 5,000 (1:N) / 100,000 (1:1) | ||||||||||||||||||||||||
Palm Capacity | As a Primary Controller: 5,000 (Storage) As a Door Unit: 3,000 (1:N) / 5,000 (1:1) | ||||||||||||||||||||||||
Transaction Buffer | 5,000,000 Events | ||||||||||||||||||||||||
Access Level | 100,000 Levels | ||||||||||||||||||||||||
On-Board Access Point Control | 1 access point on board | ||||||||||||||||||||||||
On-Board Reader Support | 2 (OSDP over RS-485) or 2 (Wiegand) with on-board IO | ||||||||||||||||||||||||
Maximum Access Points | 129 (with 32pcs AHDU-1460 modules through TCP/IP connection) 97 (with 24pcs AHDU-1460 modules through Armatura RS-485 over RS-485 connection) |
||||||||||||||||||||||||
Maximum Readers | 258 (with 32pcs AHDU-1460 modules through TCP/IP connection) 194 (with 24pcs AHDU-1460 modules through Armatura RS-485 over RS-485 connection) |
||||||||||||||||||||||||
Maximum Inputs | 12,801 (with AHSC-1000 on board IO and 32pcs AHDU-1460 modules through TCP/IP connection + 792pcs AHEB-1602 IO Expansion Board through OSDP over RS-485 connection) | ||||||||||||||||||||||||
Maximum Outputs | 12,801 (with AHSC-1000 on board IO and 32pcs AHDU-1460 modules through TCP/IP connection + 792pcs AHEB-1602 IO Expansion Board through OSDP over RS-485 connection) | ||||||||||||||||||||||||
Maximum IO Board (Access Control Mode) | 792pcs ( 24pcs direct connection through Armatura RS-485connection + 768 pcs through AHDU-1460 module through TCP/IP connection) |
||||||||||||||||||||||||
Maximum IO Board (Elevator Control Mode) | 8pcs*AHEB-1616 (direct connection through Armatura RS-485 connection) for Max.128 floors Management 16pcs*AHEB-0808 (direct connection through Armatura RS-485 connection) for Max.128 floors Management 24pcs*AHEB-1602(direct connection through Armatura RS-485 connection) for Max.48 floors Management |
||||||||||||||||||||||||
Maximum DU Modules | 32pcs (1*TCP/IP communication with AES-256 & TLS1.2 end to end secure channel) 24pcs (Armatura RS-485 communication with AES-256 end to end secure channel) |
Door Unit Controller Interface | |||||||||||||||||||||||||
Input Voltage | 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader | ||||||||||||||||||||||||
Maximum Input Current | 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader | ||||||||||||||||||||||||
TCP/IP Mode | Ethernet: 100Base-TX | ||||||||||||||||||||||||
TCP/IP Protocol | 802.1X, VLAN, SSH, IPv4, IPv6, WebSocket | ||||||||||||||||||||||||
TCP/IP Encryption | Complied up to TLS1.2, AES-256 end to end secured communication channel | ||||||||||||||||||||||||
TCP/IP Communication | Spada Protocol over WebSocket | ||||||||||||||||||||||||
RS-485 Protocol | AES-256, Armatura RS-485 Secure Channel | ||||||||||||||||||||||||
Armatura RS-485 Mode | 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit. | ||||||||||||||||||||||||
Data Inputs | TCP/IP standard supported. Maximum TCP/IP cable length: 330ft. (100m) RS-485 standard supported. Maximum RS-485 cable length: 3937ft. (1200m) |
||||||||||||||||||||||||
RFID / Biometrics Reader Interface | |||||||||||||||||||||||||
Input Voltage | 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader | ||||||||||||||||||||||||
Maximum Input Current | 12 -24 Vdc +/- 10% regulated, 500 mA maximum each reader | ||||||||||||||||||||||||
RS-485 Protocol | AES-128, OSDP Secure Channel | ||||||||||||||||||||||||
OSDP Mode | 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit. 3rd Party reader: support OSDP V2.2 or above | ||||||||||||||||||||||||
Wiegand | Read: support up to 128 bits / Write: Support 26 / 34 / 37 bit, and other customised card formats | ||||||||||||||||||||||||
Tamper Input (Wiegand) | TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum | ||||||||||||||||||||||||
Buzzer Output (Wiegand) | TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum | ||||||||||||||||||||||||
LED Output (Wiegand) | TTL levels, high > 3 V, low < 0.5 V, 5 mA source/sink maximum | ||||||||||||||||||||||||
Data Inputs | RS-485, OSDP and Wiegand standards supported. Maximum RS-485 /OSDP cable length: 3937ft. (1200m) Maximum Wiegand cable length: 328ft (100m) | ||||||||||||||||||||||||
IO Expansion Board Interface | |||||||||||||||||||||||||
RS-485 Protocol | TLS 1.2, AES-128, OSDP V2.2 Secure Channel | ||||||||||||||||||||||||
OSDP Mode | 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit. | ||||||||||||||||||||||||
Data Inputs | OSDP standards supported. Maximum cable length: 3937ft. (1200m) |