Features:
- Bundle includes 1pc AHEB-0808 Core Controller & ENC-1B
- (pre-installed in the ENC-1B . IO Expansion Board)
- 1*RS-485
- 8*supervised input (AUX IN)
- 8*relay output (AUX OUT)
- 1* power Input (PWR IN)
- 1*power output (PWR OUT)
- 1*power detection (AC fail)
- 1* backup battery detection (BAT Fail)
- 1*tamper input (TMPR)
- Inputs: 4 state supervision, resistor values (5% tolerance)
- Outputs:8 relays, 8* Form-C with dry contacts
- RS485 Connectivity: RS485 standard / OSDP V2.2
- Power & Relays: 12 - 24 VDC ± 20%, 550 mA maximum
Specifications |
||||
AHEB-0808 | ||||
Primary Power | 12 - 24 VDC ± 20%, 550 mA maximum | |||
On-Board Firmware | Dual Function Firmware for Access Control Mode & Elevator Control Mode (Automatic Operation Mode Swapping According to AHSC-1000 / AHDU Series Controller Settings) |
|||
RS-485 Connectivity | Input: RS-485 standard / OSDP V2.2 (Dedicated for AHSC-1000/ AHDU series controller communication) Output: RS-485 standard / OSDP V2.2 (Dedicated for AHEB series I/O expansion board communication) |
|||
Number of Ports | 1*RS-485 8*supervised input (AUX IN) 8*relay output (AUX OUT) 1* power Input (PWR IN) 1*power output (PWR OUT) 1*power detection (AC Fail) 1* backup battery detection (BAT Fail) 1*tamper input (TMPR) | |||
Inputs |
8 inputs 4 state supervision, resistor values (5% tolerance),4 state supervision, resistor values (5% tolerance),Normally open contact: use 1.2k, 2.2k. 4.7k or 10k |
|||
Outputs | 8 relays 8* Form-C with dry contacts | |||
AHSC/ AHDU Interface (Access Control Mode and Elevator Control Mode) | ||||
RS-485 Protocol | AES-128, OSDP V2 Secure Channel | |||
OSDP Mode | 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and1 stop bit. | |||
Max. Supported Floor (Elevator Control Mode) | Max.128 floors Management, Upon Combination Suggested Configuration: 1pcs of AHDU-1260 Controller with 8pcs*AHEB-1616 (direct connection through Armatura RS-485 connection) Note: All the Relay Ports (exclude the Fire Alarm Port) of AHSC-1000 & AHDU Series Controller Can be Utilized for Floor Management |
|||
Advanced Elevator Control Functions | N/A | |||
General Elevator Control Functions | YES | |||
Data Inputs | OSDP standards supported. Maximum cable length: 3937ft. (1200m) |
Cable Requirement | |||||||
Power & Relays | 12 - 24 VDC ± 20%, 550 mA maximum | ||||||
RS-485 Port | One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG, Maximum cable length: 3937ft (1200m) | ||||||
Mechanical | |||||||
Dimensions | 7.6” W x 4.6” L x 0.7” H (193 x 116 x 17.5mm) | ||||||
Weight | 162g (5.71oz) | ||||||
Mounting | Wall Mount | ||||||
Environmental | |||||||
Temperature | −4°F~131°F(-20°C~55°C),Operating & Storage | ||||||
Humidity | 0-95% RHNC | ||||||
Certification(s) | CE, FCC, RoHS, UL294 | ||||||
Security Rating | Data Storage Encrypted with Certified EAL6+ Crypto Chipset | ||||||
Software Interface | |||||||
Supported Software | Armatura One Security System |